ITG-2000 / XTG-2000 online thickness gauges measure the thickness of ferrous & non-ferrous metal strip on cold rolling mills/coating lines/strip processing lines. The system is supplied with custom fabricated C-frame which is designed to prevent sensors from oil/coolant ingress and are designed rugged to tolerate strip hit during coil breakage etc. and for maintenance free operation. Hundreds of installations Worldwide are evidence of the market acceptance and capability of our ITG-2000/XTG-2000 systems.
Radiation source | : | 1 Ci AM 241 | |||||||
Air Gap | : | 200 mm | |||||||
AGC output | : | ±10V, 1msec response time | |||||||
Statistical Noise | : | @ 2 Sigma Values | |||||||
Time Constant | |||||||||
Thickness | 20m sec. | 50m sec. | 100m sec. | ||||||
At 0.15mm | ±4.0µm | ±2.6µm | ±1.8µm | ||||||
At 1.0mm | ±0.70% | ±0.35% | ±0.26% | ||||||
At 2.0mm | ±0.60% | ±0.32% | ±0.21% | ||||||
At 3.0mm | ±0.60% | ±0.28% | ±0.26% | ||||||
At 4.0mm | ±0.70% | ±0.35% | ±0.32% | ||||||
At 5.0mm | ±0.87% | ±0.48% | ±0.35% | ||||||
Radiation source | : | 3 Ci AM 241 | |||||||
Air Gap | : | 200 mm | |||||||
AGC output | : | ±10V, 1msec response time | |||||||
Statistical Noise | : | @ 2 Sigma Values | |||||||
Time Constant | |||||||||
Thickness | 10m sec. | 20m sec. | 50m sec. | 100m Sec. | |||||
At 0.15mm | ±3.2µm | ±2.3µm | ±1.5µm | ±1.0µm | |||||
At 1.0mm | ±0.56% | ±0.40% | ±0.20% | ±0.15% | |||||
At 2.0mm | ±0.42% | ±0.30% | ±0.18% | ±0.12% | |||||
At 3.0mm | ±0.45% | ±0.32% | ±0.16% | ±0.15% | |||||
At 4.0mm | ±0.56% | ±0.40% | ±0.20% | ±0.18% | |||||
At 5.0mm | ±0.70% | ±0.50% | ±0.28% | ±0.20% |